Heavy Fuel Oil Motor Power Plant

Characteristic Data:

Power output: approx. 80 - 400 MW
Gross Electrical efficiency: approx. 49%
Fuel: Heavy Fuel Oil / Diesel
Nominal steam flow rate: 30 - 150 t/h

Steam parameters:

  • Live steam pressure: 25 bar
  • Live steam temperature: 350 °C
  • Live steam mass flow: 30 – 150 t/h

Type of cooling:

  • Air-cooling / wet cooling tower

Project description:

  • MAN Turbo & Diesel designs DCC power plans with a wide range of possible power output
  • Envi Con task was to optimize the basic design regarding water-steam cycle in order to maximize efficiency and reduce total costs
  • Further optimization should be done regarding general plant layout and boiler arrangement

 Scope of services:

  • Basic design
  • Layout planning
  • Preparation of RfQ
  • Bid evaluation / technical clarification